The elink body fat scale SDK is a Bluetooth development tool provided to elink partners. The SDK implements and encapsulates the elink Bluetooth protocol and is responsible for the communication between the mobile phone App and the Bluetooth body fat scale device. Bluetooth body fat scale application.
Partners who need to personalize their Android Bluetooth body fat scale APP.
repositories {
flatDir {
dirs 'libs'
}
}
Step 1. Add the JitPack repository to your build file
Add it in your root build.gradle at the end of repositories:
allprojects {
repositories {
...
maven { url 'https://jitpack.io' }
}
}
Step 2. Add the dependency
dependencies {
implementation 'com.github.elinkthings:BodyFatScaleSDKRepositoryAndroid:1.2.4'
}
You can also use aar package dependency,Please download it into the project's libs yourself
<!-In most cases, you need to ensure that the device supports BLE .-->
<uses-feature
android: name = "android.hardware.bluetooth_le"
android: required = "true" />
<uses-permission android: name = "android.permission.BLUETOOTH" />
<uses-permission android: name = "android.permission.BLUETOOTH_ADMIN" />
<!-Android 6.0 and above. Bluetooth scanning requires one of the following two permissions. You need to apply at run time .-->
<uses-permission android: name = "android.permission.ACCESS_COARSE_LOCATION" />
<uses-permission android: name = "android.permission.ACCESS_FINE_LOCATION" />
<!-Optional. If your app need dfu function .-->
<uses-permission android: name = "android.permission.INTERNET" />
6.0 and above systems need to locate permissions and need to obtain permissions manually
First configure the key and secret for the SDK, application address
// Called in the application of the main project AiFitSDK.getInstance (). Init (this, key, secret);
Add below AndroidManifest.xml application tag
<application> ... <service android:name="aicare.net.cn.iweightlibrary.wby.WBYService"/> </application>
You can directly make your own
Activity
class extendBleProfileServiceReadyActivity
public class MyActivity extends BleProfileServiceReadyActivity
@Override
protected void onCreate (Bundle savedInstanceState) {
super.onCreate (savedInstanceState);
// Judge whether the mobile device supports Ble
if (! ensureBLESupported ()) {
T.showShort (this, R.string.not_support_ble);
finish ();
}
// Judge whether there is positioning permission, this method is not encapsulated. The specific code can be obtained in the demo, or you can call the permission method in your own way.
initPermissions ();
// Judge whether Bluetooth is on, if you need to change the style, you can do it yourself
if (! isBLEEnabled ()) {
showBLEDialog ();
}
}
The APIs related to scanning are as follows. For details, please refer to the BleProfileServiceReadyActivity class. For details, refer to the sample project.
// Call the startScan method to start scanning
startScan ();
// The getAicareDevice (final BroadData broadData) interface will call back to get a body fat scale device that complies with the Aicare protocol
@Override
protected void getAicareDevice (BroadData broadData) {
// Body fat scale equipment in compliance with Aicare protocol
}
// Call the stopScan method to stop scanning
stopScan ();
// Call the isScanning method to see if it is scanning true: scanning; false: scanning stopped
isScanning ();
Note: If it is a broadcast scale, you do not need to perform the connection operation. You can directly get the body fat data in the scan callback getAicareDevice (BroadData broadData) method. The broadcast scale calls stopScan () to get back no data.
@Override
protected void getAicareDevice (BroadData broadData) {
// Broadcast scale can get data directly here
if (broadData.getDeviceType () == AicareBleConfig.BM_09) {
if (broadData.getSpecificData ()! = null) {
BM09Data data = AicareBleConfig.
getBm09Data (broadData.getAddress (), broadData.getSpecificData ());
} else if (broadData.getDeviceType () == AicareBleConfig.BM_15) {
if (broadData.getSpecificData ()! = null) {
BM15Data data = AicareBleConfig.getBm15Data (broadData.getAddress (),
broadData.getSpecificData ());
}
} else {
if (broadData.getSpecificData ()! = null) {
WeightData weightData =
AicareBleConfig.getWeightData (broadData.getSpecificData ());
}
}
}
The APIs related to the connection are as follows, please refer to the BleProfileServiceReadyActivity class for details.
// Call the startConnect method to connect the body fat scale device
// can be obtained in the getAicareDevice (BroadData broadData) callback method.
// If there is no filtering in getAicareDevice (BroadData broadData), the broadcast should be filtered when connecting, see the demo connection for details.
startConnect (String address)
// You can get the connection status in onStateChanged
@Override
public void onStateChanged (String deviceAddress, int state) {
super.onStateChanged (deviceAddress, state);
// state See the class description for specific status
}
// Call the disconnect method in WBYService.WBYBinder class to disconnect the body fat scale
binder.disconnect ()
Use the
startConnect
method to connect to the body fat scale, use theonStateChanged
method to monitor the status of the connection, and use theonError
method to monitor for exceptions during the connection process, in order to facilitate additional processing and troubleshooting. Use theisDeviceConnected
method to determine whether a connection has been established.
The following methods or interfaces are automatically obtained directly after inheriting the BleProfileServiceReadyActivity class
// OnServiceBinded method to get an instance of WBYService.WBYBinder
@Override
protected void onServiceBinded (WBYService.WBYBinder binder) {
this.binder = binder;
}
// The change and stable weight data and temperature returned by the device (supported by AC03)
@Override
protected void onGetWeightData (WeightData weightData) {
// If you want to get broadcast scale data here. Need to be in getAicareDevice (final BroadData broadData) method
// Call onGetWeightData (WeightData weightData) to pass the data through
}
// Get the setting status in the onGetSettingStatus method. For details, see AicareBleConfig.SettingStatus
@Override
protected void onGetSettingStatus (int status) {
}
// Get the version number, measurement time, user number, and impedance value in the onGetResul method
@Override
protected void onGetResult (int index, String result) {
}
// Get the device to return historical data or body fat data. True is historical data.
//Body fat data will only be generated after the current user is synchronized after STATE_INDICATION_SUCCESS
@Override
protected void onGetFatData (boolean isHistory, BodyFatData bodyFatData) {
}
// Get information about the number of decimal places returned by the device
@Override
protected void onGetDecimalInfo (DecimalInfo decimalInfo) {
}
// Algorithm sequence information returned by the device
@Override
protected void onGetAlgorithmInfo (AlgorithmInfo algorithmInfo) {
}
Note: Some of these interfaces or methods require APP to issue commands to body fat to return data.
AicareBleConfig.getBodyFatData(AlgorithmUtil.AlgorithmType.TYPE_AIC
ARE, bodyFatData.getSex(), bodyFatData.getAge(),
Double.valueOf(ParseData.getKgWeight(bodyFatData.getWeight(),
bodyFatData.getDecimalInfo())), bodyFatData .getHeight(),
bodyFatData.getAdc());
## Give instructions to the device
Get an instance of WBYService.WBYBinder in BleProfileServiceReadyActivity.onServiceBinded (WBYService.WBYBinder binder), and call the method in binder
@Override protected void onServiceBinded (WBYService.WBYBinder binder) { this.binder = binder; } // If the history is obtained binder.syncHistory (); // Part of the method of WBYBinder public class WBYBinder extends LocalBinder {
/ ** * Get history * / @Deprecated public void syncHistory () { mManager.sendCmd (AicareBleConfig.SYNC_HISTORY, AicareBleConfig.UNIT_KG); }
/ ** * Synchronize the current user * * @param user * / public void syncUser (User user) { if (user == null) { return; } mManager.syncUser (user); }
/ ** * Synchronized user list * * @param userList * / @Deprecated public void syncUserList (List userList) { mManager.syncUserList (userList); }
/ ** * Sync current unit * * @param unit {@link AicareBleConfig # UNIT_KG} * {@link AicareBleConfig # UNIT_LB} * {@link AicareBleConfig # UNIT_ST} * {@link AicareBleConfig # UNIT_JIN} * / public void syncUnit (byte unit) { mManager.sendCmd (AicareBleConfig.SYNC_UNIT, unit); }
/ ** * synchronised time * / @Deprecated public void syncDate () { mManager.syncDate (); }
/ ** * Query Bluetooth version information * / @Deprecated public void queryBleVersion () { mManager.sendCmd (AicareBleConfig.GET_BLE_VERSION, AicareBleConfig.UNIT_KG); }
/ ** * Update user information * * @param user * / @Deprecated public void updateUser (User user) { if (user == null) { return; } mManager.updateUser (user); }
/ ** * Setting mode * / public void setMode (@ AicareBleConfig.MODE int cmd) { mManager.setMode (cmd); }
/ ** * Check if authorized * / @Deprecated public void auth () { mManager.auth (); }
/ ** * Set DID * * @param did * / @Deprecated public void setDID (int did) { mManager.sendDIDCmd (AicareBleConfig.SET_DID, did); }
/ ** * Query DID * / @Deprecated public void queryDID () { mManager.sendDIDCmd (AicareBleConfig.QUERY_DID, 0); }
/ ** * Get the number of decimal places * / public void getDecimalInfo () { mManager.getDecimalInfo (); } … }
## Class description
- aicare.net.cn.iweightlibrary.entity.AlgorithmInfo (Algorithm Sequence Information)
| Type | Parameter |Description
| ---|---|---
| double |weight | weight
| int | algorithmId |algorithm ID
| int | adc | impedance value
| DecimalInfo| decimalInfo|number of decimal places
- BM09Data (BM09 data)
| Type | Parameter |Description
| ---|---|---
| int |agreementType|agreement type
| int| unitType|unit type
| DecimalInfo| decimalInfo|Decimal places
| double| weight|Weight
| int| adc|impedance value
| double| temp|temperature
| int |algorithmId|algorithm ID
| int |did|currently useless
| String |bleVersion|Bluetooth version
| int| bleType|Bluetooth type (0x09)
| String |address|device address
| long |timeMillis |measurement timestamp
| whether |boolean |isStable is stable
- BM15Data (BM15 data)
| Type | Parameter |Description
| ---|---|---
| String |version|Bluetooth version
| int| agreementType|agreementType
| int| unitType|unitType
| double |weight|weight
| int| adc|impedance value
| double| temp |temperature (if temp = 6553.5, the scale does not support temperature)
| int |algorithmId |algorithm ID
| int |did |currently useless
| int| bleType|Bluetooth type (0x15)
| String |address|device address
- BodyFatData
| Type | Parameter |Description
| ---|---|---
| String |date|measurement date
| String |time|time
| double |weight|weight
| double |bmi|
| double |bfr|
| double |sfr|
| int |uvi|visceral fat index
| double| rom|muscle rate
| double| bmr |basal metabolic rate
| double| bm |bone mass
| double| vwc |moisture content
| double| bodyAge |
| double| pp |protein rate
| int| number
| int |sex
| int |age |(1; male; 2, female)
| int |height
| int| adc|impedance value
- BroadData (broadcast data)
| Type | Parameter |Description
| ---|---|---
| String| name|device name
| String |address|device address
| boolean |isBright|Whether the screen is bright
| int| rssi|signal value
| byte |[] specificData|broadcast data
| int |deviceType|device type
- DecimalInfo (decimal point information)
| Type | Parameter |Description
| ---|---|---
| int |sourceDecimal|source data decimal places
| int |kgDecimal|kg number of decimal places
| int |lbDecimal|lb decimal places
| int |stDecimal|st number of decimal places
| int |kg|Graduation kg
| int| lb|Graduation lb
- User (User Information)
| Type | Parameter |Description
| ---|---|---
| int| id|
| int |sex|
| int |age |(1; male; 2, female)
| int |height|
| int |weight|
| int |adc|impedance (deprecated)
- WeightData (weight data)
| Type | Parameter |Description
| ---|---|---
| int |cmdType|command type (1, change; 2, stable; 3, in impedance measurement)
| double| weight|
| double| temp |temperature (if the temperature is Double.MAX_VALUE, the scale does not support temperature)
| DecimalInfo| decimalInfo
| int |adc|impedance value
| int |algorithmType|algorithm ID
| int |unitType|
| int| deviceType|device type
- cn.net.aicare.algorithmutil.BodyFatData(Calculated body fat data)
| Type | Parameter |Description
| ---|---|---
| double| bmi| Body mass index
| double| bfr| body fat rate
| double| sfr| Subcutaneous fat rate
| int |uvi| Visceral fat index
| double| rom| Rate of muscle
| int| bmr| basal metabolic rate
| double| bm| Bone Mass
| double |vwc| Water content
| int| bodyAge| physical bodyAge
| double |pp| protein percentage
- MoreFatData
| Type | Parameter |Description
| ---|---|---
| double| standardWeight| Standard weight
| double| controlWeight| Weight control
| double| fat| Fat mass
| double| removeFatWeight| Fat-free weight
| double| muscleMass| Muscle mass
| double| protein| Protein amount
| MoreFatData.FatLevel fatLevel| Obesity grade
public static enum FatLevel {
UNDER, // Underweight
THIN, // Thin
NORMAL, // standard
OVER, // Favor
FAT; overweight
}
- BleProfileService Connection Status
public static final int STATE_CONNECTING = 4; // connecting public static final int STATE_DISCONNECTED = 0; // disconnect public static final int STATE_CONNECTED = 1; // The connection was successful public static final int STATE_SERVICES_DISCOVERED = 2; // Discover services public static final int STATE_INDICATION_SUCCESS = 3; // Enable success public static final int STATE_TIME_OUT = 5; // connection timed out
- AicareBleConfig.SettingStatus Status information returned by the device
int NORMAL = 0; // Normal int LOW_POWER = 1; // Low power int LOW_VOLTAGE = 2; // Low voltage int ERROR = 3; // overload int TIME_OUT = 4; // timeout int UNSTABLE = 5; // Unstable int SET_UNIT_SUCCESS = 6; // Set unit success int SET_UNIT_FAILED = 7; // Set unit failed int SET_TIME_SUCCESS = 8; // Successfully set time int SET_TIME_FAILED = 9; // Failed to set time int SET_USER_SUCCESS = 10; // Set user successfully int SET_USER_FAILED = 11; // Failed to set user int UPDATE_USER_LIST_SUCCESS = 12; // Update user list successfully int UPDATE_USER_LIST_FAILED = 13; // Update user list failed int UPDATE_USER_SUCCESS = 14; // Update user successfully int UPDATE_USER_FAILED = 15; // Update user failed int NO_HISTORY = 16; // There is no historical data int HISTORY_START_SEND = 17; // historical data starts to be sent int HISTORY_SEND_OVER = 18; // historical data transmission is complete int NO_MATCH_USER = 19; // No matching users int ADC_MEASURED_ING = 20; // Impedance measurement int ADC_ERROR = 21; // Impedance measurement failed int REQUEST_DISCONNECT = 22; // The device requested to disconnect int SET_DID_SUCCESS = 23; // DID set successfully int SET_DID_FAILED = 24; // Set DID failed int DATA_SEND_END = 25; // Measured data transmission is complete int UNKNOWN = -1; // unknown
- WBYService Bluetooth information returned by the device
public final static int BLE_VERSION = 0; // Bluetooth version public final static int MCU_DATE = 1; // mcu date public final static int MCU_TIME = 2; // mcu time public final static int USER_ID = 3; // user number public final static int ADC = 4; // impedance value
## Version History
| Version number | Update time | Author | Update information
| ---- | --- | ----- | -----
| 1.0 | 2017/02/15 | Suzy | Preliminary version
| 1.0.1 | 2017/07/31 | Suzy | Fix some data conversion bugs
| 1.0.2 | 2017/09/11 | Suzy | The type in the instruction is set according to the type of device actually connected
| 1.0.3 | 2017/11/16 | Suzy | Code optimization
| 1.0.4 | 2018/07/12 | Suzy | compatible broadcast scale
| 1.0.5 | 2018/01/15 | Suzy | New protocol compatible
| 1.0.6 | 2018/02/25 | Suzy | Function optimization
| 1.0.7 | 2018/02/28 | Suzy | Encapsulated decimal point class
| 1.0.8 | 2018/03/14 | Suzy | Fix the bug of wrong body age
| 1.0.9 | 2018/4/9 | Suzy | Compatible with BM09 protocol
| 1.1.1 | 2018/5/10 | Suzy | Compatible with kg / lb indexing protocol
| 1.1.2 | 2018/5/11 | Suzy | Solve the bug that the st unit data is inconsistent with the scale display
| 1.1.3 | 2018/6/22 | Suzy | Solve the bug that the decimal point is sometimes not available
| 1.1.4 | 2018/7/7 | Suzy | Compatible with BM15 protocol
| 1.1.5 | 2018/7/20 | Suzy | Compatible algorithm ID protocol
| 1.1.7 | 2019/04/30 | Stan | Add BM15 body fat data calculation algorithm
| 1.1.8 | 2019/06/6 | Stan | Modify the original data to lb, st calculation error problem
| 1.1.9 | 2019/12/19 | Xing | Add history
| 1.2.0 | 2019/1/17 | Xing | Update and optimize Bluetooth library
| 1.2.1 | 2020/3/19 | Xing | Increase the calculation method of body fat data and the algorithm of lean body mass etc.
| 1.2.2 | 2020/3/23 | Xing | Modify SDK to gradle form dependency
| 1.2.3 | 2020/4/2 | Xing | Add key verification, modify the dependent environment to androidx
| 1.2.4 | 2020/4/10 | Xing | Fix known bugs
## FAQ
- How to judge whether the currently scanned BroadData (device) is a broadcast scale or a connected scale?
1. According to the value of deviceType attribute of BroadData:
deviceType == AicareBleConfig.TYPE_WEI_BROAD is a broadcast scale without temperature
deviceType == AicareBleConfig.TYPE_WEI_TEMP_BROAD is a broadcast scale with temperature
deviceType == AicareBleConfig.TYPE_WEI is a connected scale without temperature
deviceType == AicareBleConfig.TYPE_WEI_TEMP is a connected scale with temperature
- Which units does the Bluetooth protocol support?
1. Units only support up to 4 types (kg, lb, st, kg), please refer to the factory settings of the scale for specific units supported.
- Can't scan the Bluetooth device?
1. Check whether the permissions of the App are normal. The 6.0 and above systems must locate the permissions and need to manually obtain the permissions
2. Check whether the location service of the mobile phone is turned on, some mobile phones may need to turn on the GPS
3. Unplug the battery and restart the scale
4. Whether it is connected by other mobile phones (when the scale is not connected, the Bluetooth icon on the weighing pan will continue to flash)
- Which devices are supported?
1. Support BM series connection scale, BM15 broadcast scale
- How does the connected scale determine the end of measurement?
1. OnGetFatData () method callback means the measurement is completed
- How do broadcast scales determine the end of measurement?
1. All the data of the broadcast scale is returned from getAicareDevice and parsed to get the WeightData object. GetCmdType () == 3 in WeightData means the measurement is completed, please refer to the demo for details
- The data displayed by the scale is inconsistent with the data received by the app
1. The SDK will request decimals by default, and you can use getDecimalInfo () in WBYBinder to actively obtain decimals
2. When the app calculates the weight, it needs to pass in DecimalInfo (decimal object) for calculation
DecimalInfo { private int sourceDecimal; // The source data decimal places private int kgDecimal; // kg decimal places private int lbDecimal; // lb decimal places private int stDecimal; // st decimal places private int kgGraduation; // kg division private int lbGraduation; // lb division } ```
You must take off your shoes and socks and stand barefoot on the electrode pads of the body fat scale to measure body fat data.
When weighing, the scale always displays Error, and the app shows that the impedance measurement has failed. What is the reason?
Take off your shoes and socks and barefoot stand on the electrode pad of the body fat scale to measure, and then Error will no longer be displayed.
How to provide feedback to technical support staff efficiently?
The SDK will print the log on the console, please save the log as txt and send it to the technical staff when feedback the problem
When feeding back the problem, describe the operation before and after the problem as clearly as possible. It is best to record a video to tell how to reproduce the problem.
Are there any criteria and copy for body fat data?
Body fat determination standards may vary from manufacturer to manufacturer, and there is currently no industry-recognized reference standard. The following are the standards used by our company for reference only: 《Bluetooth Body Fat Scale Judgment Standard and Mini Program Copy 20200416》
Shenzhen elink things Co., Ltd.
Phone: 0755-81773367
Official website: www.elinkthings.com
Email: app@elinkthings.com